Description
The Baker DX-15 RLC PD combines full RLC measurement with partial discharge detection on the 15 kV DX-15 platform for early detection of insulation deterioration. The Megger Baker DX-15 is the 15 kV class model of the Baker DX static motor analyzer platform. It tests de-energized motors, generators and coils with low voltage measurements, high voltage DC insulation tests and surge testing in a single unit. Configurations differ in the low voltage test set (resistance only or full RLC) and in options such as partial discharge and a power pack interface. It suits larger motors and higher voltage windings in repair shops and utilities.
Key features
- 15 kV class high voltage and surge testing
- Low voltage resistance or full RLC measurement, depending on version
- Surge test for turn-to-turn insulation weakness
- Bar-to-bar armature testing on DC motors
- Touch screen graphical interface with USB printer output
- Options for partial discharge and power pack interface
Typical applications
- Testing medium voltage motors and generators
- Motor rewind acceptance testing
- Predictive maintenance in utilities and heavy industry
- Troubleshooting winding insulation faults
Specifications
| Brand | Megger |
|---|---|
| Model | Baker DX-15 |
| Order code | DX-15 RLC PD |
| Product type | Static Motor Analyzer |
| Low voltage tests | Full RLC |
| Partial discharge | Included |
| Order number | DX-15-PD-RLC-Z |
| Manufacturer number | 99-DX15-ZDS3PDRC |
| Voltage class | 15 kV |
| High voltage tests | DC tests, surge test |
| Display | Touch screen with graphical user interface |
| Printer interface | USB |





Reviews
There are no reviews yet.